Recent Update on UV Disinfection to Fulfill the Disinfection Credit Value for Enteric Viruses in Water

Nicolas Augsburger, Andri Taruna Rachmadi, Noor A. Zaouri, Yunho Lee, Pei-Ying Hong

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Ultraviolet (UV) radiation alone or in combination with other oxidation processes is increasingly being considered for water disinfection because of stringent regulatory requirements for pathogen inactivation. To fulfill this requirement, an appropriate UV dose or fluence (mJ/cm2) is applied to combat enteric viruses in surface or treated water. There is a need for a cumulative review on the effectiveness of current and emerging UV technologies against various types of human enteric viruses. We extracted the kinetics data from 52 selected experimental studies on enteric virus inactivation using low pressure (LP-UV), medium pressure (MP-UV), UV-LED, and advanced oxidation processes (AOPs) and applied a simple linear regression analysis to calculate the range of UV fluence (mJ/cm2) needed for 4-log10 inactivation. The inactivation of adenoviruses with LP-UV, MP-UV, and UV/H2O2 (10 mg/L) required the highest fluence, which ranged from 159 to 337, 45, and 115 mJ/cm2, respectively. By contrast, when using LP-UV, the inactivation of other enteric viruses, such as the Caliciviridae and Picornaviridae family and rotavirus, required fluence that ranged from 19 to 69, 18 to 43, and 38 mJ/cm2, respectively. ssRNA viruses exhibit higher sensitivity to UV radiation than dsRNA and DNA viruses. In general, as an upgrade to LP-UV, MP-UV is a more promising strategy for eliminating enteric viruses compared to AOP involving LP-UV with added H2O2 or TiO2. The UV-LED technology showed potential because a lower UV fluence (at 260 and/or 280 nm wavelength) was required for 4-log10 inactivation compared to that of LP-UV for most strains examined in this critical review. However, more studies evaluating the inactivation of enteric viruses by means of UV-LEDs and UV-AOP are needed to ascertain these observations.
Original languageEnglish (US)
JournalEnvironmental Science & Technology
DOIs
StatePublished - Dec 9 2021

Bibliographical note

KAUST Repository Item: Exported on 2021-12-14
Acknowledged KAUST grant number(s): FCC/1/1971-32-01, REI/1/4178-03-01
Acknowledgements: This study was supported by the KAUST Center Applied Research Funding FCC/1/1971-32-01, Center of Excellence for NEOM Research flagship projects REI/1/4178-03-01, and KAUST Translation Fund REI/1/4223-01-01 awarded to P.Y.-H.

ASJC Scopus subject areas

  • Environmental Chemistry
  • General Chemistry

Fingerprint

Dive into the research topics of 'Recent Update on UV Disinfection to Fulfill the Disinfection Credit Value for Enteric Viruses in Water'. Together they form a unique fingerprint.

Cite this