Abstract
Opacity transfer function (OTF) generation for direct volume rendering of medical image data is an intensely discussed subject. Several automatic methods exist for CT and MRI data, which are not apt for ultrasound data, mainly due to its low signal-to-noise ratio. Furthermore, ultrasound (US) imaging is able to produce time-varying 3D datasets in real time thus opening the door to 4D visualization. However, OTF design for 4D datasets has not been exhaustively discussed until now. We present an efficient solution to generate an optimized OTF for a given 3DUS dataset in real time. Our method results in excellent visualization which we demonstrate using 3D fetus datasets. Finally, we discuss the applicability of our method to 4DUS visualization.
Original language | English (US) |
---|---|
Pages (from-to) | 53-63 |
Number of pages | 11 |
Journal | Computerized Medical Imaging and Graphics |
Volume | 29 |
Issue number | 1 |
DOIs | |
State | Published - Jan 2005 |
Externally published | Yes |
Keywords
- 3D/4D ultrasound
- Direct volume rendering
- Transfer function
ASJC Scopus subject areas
- Radiological and Ultrasound Technology
- Radiology Nuclear Medicine and imaging
- Computer Vision and Pattern Recognition
- Health Informatics
- Computer Graphics and Computer-Aided Design