T1 - Potential Investigation of Membrane Energy Recovery Ventilators for the Management of Building Air-Conditioning Loads
AU - Ashraf, Hadeed
AU - Sultan, Muhammad
AU - Farooq, Muhammad
AU - Ibrahim, Sobhy M.
AU - Sajjad, Uzair
AU - Shahzad, Muhammad Wakil
AU - Khan, Muhammad Usman
AU - Jamil, Muhammad Ahmad
N1 - Generated from Scopus record by KAUST IRTS on 2023-09-23
PY - 2022/3/1
Y1 - 2022/3/1
N2 - The present study provides insights into the energy-saving potential of a membrane energy recovery ventilator (ERV) for the management of building air-conditioning loads. This study explores direct (DEC), Maisotsenko cycle (MEC) evaporative cooling, and vapor compression (VAC) systems with ERV. Therefore, this study aims to explore possible air-conditioning options in terms of temperature, relative humidity, human thermal comfort, wet bulb effectiveness, energy saving potential, and CO2 emissions. Eight different combinations of the above-mentioned systems are proposed in this study i.e., DEC, MEC, VAC, MEC-VAC, and their possible combinations with and without ERVs. A building was modeled in DesignBuilder and simulated in EnergyPlus. The MEC-VAC system with ERV achieved the highest temperature gradient, wet bulb effectiveness, energy-saving potential, optimum relative humidity, and relatively lower CO2 emissions i.e., 19.7◦C, 2.2, 49%, 48%, and 499.2 kgCO2/kWh, respectively. Thus, this study concludes the hybrid MEC-VAC system with ERV the optimum system for the management of building air-conditioning loads.
AB - The present study provides insights into the energy-saving potential of a membrane energy recovery ventilator (ERV) for the management of building air-conditioning loads. This study explores direct (DEC), Maisotsenko cycle (MEC) evaporative cooling, and vapor compression (VAC) systems with ERV. Therefore, this study aims to explore possible air-conditioning options in terms of temperature, relative humidity, human thermal comfort, wet bulb effectiveness, energy saving potential, and CO2 emissions. Eight different combinations of the above-mentioned systems are proposed in this study i.e., DEC, MEC, VAC, MEC-VAC, and their possible combinations with and without ERVs. A building was modeled in DesignBuilder and simulated in EnergyPlus. The MEC-VAC system with ERV achieved the highest temperature gradient, wet bulb effectiveness, energy-saving potential, optimum relative humidity, and relatively lower CO2 emissions i.e., 19.7◦C, 2.2, 49%, 48%, and 499.2 kgCO2/kWh, respectively. Thus, this study concludes the hybrid MEC-VAC system with ERV the optimum system for the management of building air-conditioning loads.
UR - https://www.mdpi.com/1996-1073/15/6/2139
UR - http://www.scopus.com/inward/record.url?scp=85126993475&partnerID=8YFLogxK
U2 - 10.3390/en15062139
DO - 10.3390/en15062139
M3 - Article
SN - 1996-1073
VL - 15
JO - Energies
JF - Energies
IS - 6
ER -