TY - JOUR
T1 - Porous polymer monolith for surface-enhanced laser desorption/ionization time-of-flight mass spectrometry of small molecules
AU - Peterson, Dominic S.
AU - Luo, Quanzhou
AU - Hilder, Emily F.
AU - Svec, Frantisek
AU - Frechet, Jean
PY - 2004/7/16
Y1 - 2004/7/16
N2 - Porous poly(butyl methacrylate-co-ethylene dimethacrylate), poly(benzyl methacrylate-co-ethylene dimethacrylate), and poly(styrene-co-divinylbenzene) monoliths have been prepared on the top of standard sample plates used for matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and the modified plates were used for laser desorption/ionization mass spectrometry (LDI-MS). The hydrophobic porous surface of these monoliths enables the transfer of sufficient energy to the analyte to induce desorption and ionization prior to TOFMS analysis. Both UV and thermally initiated polymerization using a mask or circular openings in a thin gasket have been used to define spot locations matching those of the MALDI plates. The desorption/ ionization ability of the monolithic materials depends on the applied laser power, the solvent used for sample preparation, and the pore size of the monoliths. The monolithic matrices are very stable and can be used even after long storage times in a typical laboratory environment without observing any deterioration of their properties. The performance of the monolithic material is demonstrated with the mass analysis of several small molecules including drugs, explosives, and acid labile compounds. The macroporous spots also enable the archiving of samples.
AB - Porous poly(butyl methacrylate-co-ethylene dimethacrylate), poly(benzyl methacrylate-co-ethylene dimethacrylate), and poly(styrene-co-divinylbenzene) monoliths have been prepared on the top of standard sample plates used for matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and the modified plates were used for laser desorption/ionization mass spectrometry (LDI-MS). The hydrophobic porous surface of these monoliths enables the transfer of sufficient energy to the analyte to induce desorption and ionization prior to TOFMS analysis. Both UV and thermally initiated polymerization using a mask or circular openings in a thin gasket have been used to define spot locations matching those of the MALDI plates. The desorption/ ionization ability of the monolithic materials depends on the applied laser power, the solvent used for sample preparation, and the pore size of the monoliths. The monolithic matrices are very stable and can be used even after long storage times in a typical laboratory environment without observing any deterioration of their properties. The performance of the monolithic material is demonstrated with the mass analysis of several small molecules including drugs, explosives, and acid labile compounds. The macroporous spots also enable the archiving of samples.
UR - http://www.scopus.com/inward/record.url?scp=3042823526&partnerID=8YFLogxK
U2 - 10.1002/rcm.1515
DO - 10.1002/rcm.1515
M3 - Article
C2 - 15216513
AN - SCOPUS:3042823526
SN - 0951-4198
VL - 18
SP - 1504
EP - 1512
JO - Rapid Communications in Mass Spectrometry
JF - Rapid Communications in Mass Spectrometry
IS - 13
ER -