Abstract
Reverse osmosis (RO) membranes inevitably foul because of the accumulation of material on the membrane surface. Instead of trying to reduce membrane fouling by chemically modifying the membrane, we took a different approach based on adding a sacrificial coating of two polyelectrolytes to the membrane. After membrane fouling, this coating was removed by flushing with a highly saline brine solution, and a new coating was regenerated in situ to provide a fresh protective layer (PL) on the membrane surface. The utility of this approach was demonstrated by conducting four consecutive dead-end filtration experiments using a model foulant (alginate, 200 ppm) in a synthetic brackish water (2000 ppm of NaCl). Brine removal and regeneration of the PL coating restored the water flux to an average of 97 ± 3% of its initial flux, compared to only 83 ± 3% for the pristine membrane. The average water flux for the PL-coated membranes was 15.5 ± 0.6 L m h until the flux was decreased by 10% versus its initial flux, compared to 13.4 ± 0.5 L m h for the nontreated control. The use of a sacrificial PL coating could therefore provide a more sustainable approach for addressing RO membrane fouling.
Original language | English (US) |
---|---|
Pages (from-to) | 584-590 |
Number of pages | 7 |
Journal | Environmental Science & Technology Letters |
Volume | 5 |
Issue number | 9 |
DOIs | |
State | Published - Aug 16 2018 |
Bibliographical note
KAUST Repository Item: Exported on 2020-10-01Acknowledged KAUST grant number(s): OSR-2017-CPF-2907-02
Acknowledgements: The authors thank Mr. Woochul Song and Dr. Manish Kumar's lab at The Pennsylvania State University for the loan of the dead-end filtration test device. This research was supported by the King Abdullah University of Science and Technology (KAUST) (OSR-2017-CPF-2907-02) and The Pennsylvania State University.