TY - JOUR
T1 - Physical and economical evaluation of laboratory-scale membrane bioreactor by long-term relative cost–benefit analysis
AU - Ayub, Mariam
AU - Saeed, Nadeeha
AU - Chung, Shinho
AU - Nawaz, Muhammad Saqib
AU - Ghaffour, NorEddine
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledgements: This research was conducted by support of Korean Peace Fund, Innovation Fund of ORIC, Forman Christian College University, and PHILOS Korea (provision of PVDF hollow fibre membrane.
PY - 2020/7/8
Y1 - 2020/7/8
N2 - Two laboratory-scale single-stage submerged membrane bioreactors (MBRs) were operated in parallel to examine the effect of different flux conditions and several fouling mitigation methods. After control operation (filtration only), three fouling control methods (relaxation, standard backwash and chemical backwash) at 27 LMH flux and four different flux conditions (54, 36, 27 and 18 LMH) with standard backwash were applied. Physical performance of MBRs was evaluated based on the operational duration to reach maximum transmembrane pressure and the volume of permeate produced during the operational duration. Then relative cost–benefit analysis was carried out. Results showed that the combination of chemical backwash and standard backwash was the most effective for fouling mitigation in terms of physical improvement of MBR performance. However, the combination proved less economical (400% + α relative cost) than standard backwash alone (343% relative cost), because of the additional cost for pumps and chemical. It also showed that lower flux (18 LMH) is desirable as it showed better physical performance (1,770% improvement as compared to the highest flux, 54 LMH) and proved more economical than higher flux configuration. Therefore, it is concluded that the operation with standard backwash at the lowest possible flux is the best combination to improve MBR performance as well as long-term cost–benefit.
AB - Two laboratory-scale single-stage submerged membrane bioreactors (MBRs) were operated in parallel to examine the effect of different flux conditions and several fouling mitigation methods. After control operation (filtration only), three fouling control methods (relaxation, standard backwash and chemical backwash) at 27 LMH flux and four different flux conditions (54, 36, 27 and 18 LMH) with standard backwash were applied. Physical performance of MBRs was evaluated based on the operational duration to reach maximum transmembrane pressure and the volume of permeate produced during the operational duration. Then relative cost–benefit analysis was carried out. Results showed that the combination of chemical backwash and standard backwash was the most effective for fouling mitigation in terms of physical improvement of MBR performance. However, the combination proved less economical (400% + α relative cost) than standard backwash alone (343% relative cost), because of the additional cost for pumps and chemical. It also showed that lower flux (18 LMH) is desirable as it showed better physical performance (1,770% improvement as compared to the highest flux, 54 LMH) and proved more economical than higher flux configuration. Therefore, it is concluded that the operation with standard backwash at the lowest possible flux is the best combination to improve MBR performance as well as long-term cost–benefit.
UR - http://hdl.handle.net/10754/664126
UR - https://iwaponline.com/jwrd/article/doi/10.2166/wrd.2020.023/75290/Physical-and-economical-evaluation-of
U2 - 10.2166/wrd.2020.023
DO - 10.2166/wrd.2020.023
M3 - Article
SN - 2220-1319
JO - Journal of Water Reuse and Desalination
JF - Journal of Water Reuse and Desalination
ER -