Abstract
Transmission electron microscopy (TEM) characterization of nickel contacts to bulk bismuth tellurium selenide [Bi2(Te, Se)3] is reported. Samples were prepared in a dual column focused ion beam/scanning electron microscope (FIB/SEM) system using a lift-out technique, with ion beam energy and exposure times carefully optimized to minimize sample damage. Diffusion of Ni into Bi2(Te, Se)3 was observed and the formation of a nickel telluride (NiTe) interfacial region confirmed after heat treatment at 200 °C. Selected area diffraction patterns provided evidence of a modified bismuth telluride-like structure at the interface, identified by analytical electron microscopy to be composed of Ni and Bi2(Te, Se)3.
Original language | English (US) |
---|---|
Pages (from-to) | 440-444 |
Number of pages | 5 |
Journal | Surface and Interface Analysis |
Volume | 41 |
Issue number | 5 |
DOIs | |
State | Published - May 2009 |
Externally published | Yes |
Keywords
- Electron energy loss spectroscopy
- Focused ion beam
- Thermoelectric materials
- Transmission electron microscopy
- X-ray diffraction
ASJC Scopus subject areas
- General Chemistry
- Condensed Matter Physics
- Surfaces and Interfaces
- Surfaces, Coatings and Films
- Materials Chemistry