TY - JOUR
T1 - Integrated Assessment of Left Ventricular Electrical Activation and Myocardial Strain Mapping in Heart Failure Patients
T2 - A Holistic Diagnostic Approach for Endocardial Cardiac Resynchronization Therapy, Ablation of Ventricular Tachycardia, and Biological Therapy
AU - Maffessanti, Francesco
AU - Prinzen, Frits W.
AU - Conte, Giulio
AU - Regoli, François
AU - Caputo, Maria Luce
AU - Suerder, Daniel
AU - Moccetti, Tiziano
AU - Faletra, Francesco
AU - Krause, Rolf
AU - Auricchio, Angelo
N1 - Publisher Copyright:
© 2018 The Authors
PY - 2018/1
Y1 - 2018/1
N2 - Objectives This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. Background The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. Methods In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (Ecc) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure Ecc and local area strain (LAS) from the motion field of the AEMM catheter tip. Results Intertechnique agreement for Ecc was good (R2 = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (−0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: Ecc (median [first to third quartile]: nonscar −0.10 [−0.15 to −0.06] vs. scar −0.04 [−0.06 to −0.02]) and LAS (−0.20 [−0.27 to −0.14] vs. −0.09 [−0.14 to −0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. Conclusions An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their intraprocedural evaluation.
AB - Objectives This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. Background The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. Methods In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (Ecc) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure Ecc and local area strain (LAS) from the motion field of the AEMM catheter tip. Results Intertechnique agreement for Ecc was good (R2 = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (−0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: Ecc (median [first to third quartile]: nonscar −0.10 [−0.15 to −0.06] vs. scar −0.04 [−0.06 to −0.02]) and LAS (−0.20 [−0.27 to −0.14] vs. −0.09 [−0.14 to −0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. Conclusions An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their intraprocedural evaluation.
KW - cardiac magnetic resonance
KW - electromechanical mapping
KW - endocardial mapping
KW - heart failure
KW - scar tissue
KW - strain imaging
UR - http://www.scopus.com/inward/record.url?scp=85032961705&partnerID=8YFLogxK
U2 - 10.1016/j.jacep.2017.08.011
DO - 10.1016/j.jacep.2017.08.011
M3 - Article
C2 - 29600778
AN - SCOPUS:85032961705
SN - 2405-500X
VL - 4
SP - 138
EP - 146
JO - JACC: Clinical Electrophysiology
JF - JACC: Clinical Electrophysiology
IS - 1
ER -