Abstract
Quartz crystal microbalance (QCM) coated with poly-4-vinylpyridine (PVP) and metal organic framework HKUST-1 are investigated and compared for humidity sensing. Drop casting method is employed to coat the PVP and HKUST-1 solutions onto the surface of a quartz crystal microbalance. The resonance frequencies of these sensors with varying relative humidity (RH) from 22% RH to 69% RH are measured using impedance analysis method. The sensitivity, humidity hysteresis, response, and recovery times of these sensors are studied. The sensitivities of uncoated, PVP, and HKUST-1 coated QCM sensors are 7 Hz, 48 Hz, and 720 Hz, respectively, in the range of 22% RH–69% RH. The extraction of desorption rate and adsorption energy associated with the adsorption and desorption of water molecules on these surfaces reveals that HKUST-1 has better sensing properties than PVP and uncoated QCM sensors. In this work, the HKUST-1 coated QCM is shown to be a promising material for moisture detection.
Original language | English (US) |
---|---|
Pages (from-to) | 1-8 |
Number of pages | 8 |
Journal | Journal of Sensors |
Volume | 2016 |
DOIs | |
State | Published - Jul 31 2016 |
Bibliographical note
KAUST Repository Item: Exported on 2020-10-01Acknowledgements: The authors are thankful to Dr. Osama Shekhah and Professor Mohamed Eddaoudi for providing and helping in preparing HKUST-1. This research has been supported by KAUST.