Abstract
The effect of DC electric field on the behaviors of spreading flame over polyethylene (PE)-insulated twin electrical wires was investigated by varying the wire gap (S) and voltage (VDC). The twin flame spreads with the same flame spread rate (FSR) independently when no electric field is applied. With an applied DC electric field, the twin flame interacts such that FSR, flame width, and the leaning direction of interacting twin flames vary appreciably. The spread rate for wire flame with negative voltage (SF-) was larger than that with positive voltage (SF+) during transient period and then the two became the same in a developed region (a quasi-steady spread). Such a flame behavior could be grouped into two: twin flame spread (regime I) and single flame spread (regime II) after the extinction of SF+. Each regime could be categorized into three sub-regimes depending on S and VDC. For small VDC, the flame leaned toward the burnt wire, reducing FSR. With further increasing VDC, FSR increased due to the ionic wind effect and then decreased via the mass loss of molten PE. These non-monotonic behavior of FSR with DC voltage can be attributed the behaviors of molten PE, exhibiting dripping, electrospray, and di-electrophoresis phenomena. For further increased voltage, the flames were extinguished by streamer generation and an electrical short occurred at excessive voltages.
Original language | English (US) |
---|---|
Title of host publication | Volume 3A: Fluid Applications and Systems |
Publisher | American Society of Mechanical Engineers |
ISBN (Print) | 9780791859049 |
DOIs | |
State | Published - Nov 20 2019 |
Bibliographical note
KAUST Repository Item: Exported on 2020-10-01Acknowledgements: This work was supported by the SGER Program through the National Research Foundation (NRF) of Korea funded by the Ministry of Education, Science, and Technology (2018–2019). SHC and MSC were supported by King Abdullah University of Science and Technology.