Abstract
This corrigendum corrects the definition of the preignition criterion stated on page 184. It should read: “By our observation, whenever Da* = τchar /τign < 0.0005 for the Ar containing mixture, preignition can likely affect the ignition process. However, at higher temperatures (Da* > 0.0005), the chemical process is dominant and homogeneous ignition is observed.” Given this revised definition, the demarcation of blue vertical line in the right plot of Figure 11 should be “τchar /τign < 0.0005”. The revised figure is given below.
Original language | English (US) |
---|---|
Article number | 112104 |
Journal | Combustion and Flame |
Volume | 241 |
DOIs |
|
State | Published - Jul 2022 |
Bibliographical note
Publisher Copyright:© 2022 The Combustion Institute
ASJC Scopus subject areas
- General Chemistry
- General Chemical Engineering
- Fuel Technology
- Energy Engineering and Power Technology
- General Physics and Astronomy